Back to Product Page
HEAVY
DUTY ALUMINUM CROSSOVER BRIDGE
1,000 LBS. CAPACITY
|
|
|
|
IBC
INDUSTRIAL DESIGN SHOWN ABOVE
|
|
STRONG-ATTRACTIVE-WEATHER
RESISTANT |
|
Acceptable
Usage: For industrial/commercial maintenance access
and industrial/commercial storage access. |
|
Quality engineered to your specific height requirements
Designed for safety and convenience
Heavy
duty aluminum I bar grating stair treads wont sag or
dish (supplied as standard).
Factory welded handrails of 1 1/2" x .125 square tubing.
2 rail system with toeguard (standard).
10"
x 2.6" aluminum (6061-T6511) structural channel stringers.
Structural connections are made with 5/8" dia.
Bolts and 3/8" butt plates.
Fire proof construction.
Available in 2 tread widths.
Meets OSHA requirements. See OSHA standard 1910.25
(Fixed Industrial Stairs) listed below price table.
Standard mill finish aluminum.
Provides safe walkways over conveyors, pipes and other
obstacles.
Choose 36" or 48" tread width - special sizes available
upon request.
Overall width = tread width + 5.25".
Stainless Steel assembly hardware included.
|
|
STAIR
SECTIONS AVAILABLE IN 2 STYLES
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
33° ANGLE AND 10 15/16" DEEP TREADS
|
|
45° ANGLE AND
9 13/16" DEEP TREADS
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CUSTOM
SIZES - SAME DAY QUOTES
|
Custom
sizes and configurations are readily available. We provide same
day price quotes if you require a special
stair angle, specific tread rise/run, or a maximum horizontal
stair run to satisfy available floor space constraints. |
|
|
|
|
|
|
|
|
|
Aluminum
I Bar Grating with Stainless Steel
Assembly Hardware Treads provided with
corrugated aluminum nosing. |
|
Top
View of 45 Deg. Rail
|
|
|
Top
View of 32 Deg. Rail
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rugged
heavy duty industrial grade construction
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Order
Online, by Phone, or by E-Mail |
|
|
|
~
Add items to your online shopping cart ~
Click a Price of the item you
wish to purchase.
|
|
|
PRICES
|
MODEL NO. |
UNDER
CLEARANCE |
SPAN |
TREAD
WIDTH |
OSHA
HORIZONTAL
RUN (In.) |
BOCA
HORIZONTAL
RUN (In.) |
OSHA PRICE
LIST |
BOCA PRICE
LIST |
2424-BG-36-AL
|
24 |
24 |
36 |
82
1/8
|
140
15/16
|
|
|
2424-BG-48-AL
|
24 |
24 |
48 |
82
1/8
|
140
15/16
|
|
|
2436-BG-36-AL
|
24 |
36 |
36 |
94
1/8
|
152
15/16
|
|
|
2436-BG-48-AL
|
24 |
36 |
48 |
94
1/8
|
152
15/16
|
|
|
2448-BG-36-AL
|
24 |
48 |
36 |
106
1/8
|
164
15/16
|
|
|
2448-BG-48-AL
|
24 |
48 |
48 |
106
1/8
|
164
15/16
|
|
|
3624-BG-36-AL
|
36 |
24 |
36 |
101
1/8
|
184
15/16
|
|
|
3624-BG-48-AL
|
36 |
24 |
48 |
101
1/8
|
184
15/16
|
|
|
3636-BG-36-AL
|
36 |
36 |
36 |
113
1/8
|
196
15/16
|
|
|
3636-BG-48-AL
|
36 |
36 |
48 |
113
1/8
|
196
15/16
|
|
|
3648-BG-36-AL
|
36 |
48 |
36 |
125
1/8
|
208
15/16
|
|
|
3648-BG-48-AL
|
36 |
48 |
48 |
125
1/8
|
208
15/16
|
|
|
4824-BG-36-AL
|
48 |
24 |
36 |
139
1/8
|
229
15/16
|
|
|
4824-BG-48-AL
|
48 |
24 |
48 |
139
1/8
|
229
15/16
|
|
|
4836-BG-36-AL
|
48 |
36 |
36 |
151
1/8
|
241
15/16
|
|
|
4836-BG-48-AL
|
48 |
36 |
48 |
151
1/8
|
241
15/16
|
|
|
4848-BG-36-AL
|
48 |
48 |
36 |
163
1/8
|
253
15/16
|
|
|
4848-BG-48-AL
|
48 |
48 |
48 |
163
1/8
|
253
15/16
|
|
|
6024-BG-36-AL
|
60 |
24 |
36 |
158
1/8
|
249
13/16
|
|
|
6024-BG-48-AL
|
60 |
24 |
48 |
158
1/8
|
249
13/16
|
|
|
6036-BG-36-AL
|
60 |
36 |
36 |
170
1/8
|
261
13/16
|
|
|
6036-BG-48-AL
|
60 |
36 |
48 |
170
1/8
|
261
13/16
|
|
|
6048-BG-36-AL
|
60 |
48 |
36 |
182
1/8
|
273
13/16
|
|
|
6048-BG-48-AL
|
60 |
48 |
48 |
182
1/8
|
273
13/16
|
|
|
7224-BG-36-AL
|
72 |
24 |
36 |
172
5/16
|
295
7/8
|
|
|
7224-BG-48-AL
|
72 |
24 |
48 |
172
5/16
|
295
7/8
|
|
|
7236-BG-36-AL
|
72 |
36 |
36 |
184
5/16
|
307
7/8
|
|
|
7236-BG-48-AL
|
72 |
36 |
48 |
184
5/16
|
307
7/8
|
|
|
7248-BG-36-AL
|
72 |
48 |
36 |
196
5/16
|
319
7/8
|
|
|
7248-BG-48-AL
|
72 |
48 |
48 |
196
5/16
|
319
7/8
|
|
|
8424-BG-36-AL
|
84 |
24 |
36 |
191
1/2
|
340
3/16
|
|
|
8424-BG-48-AL
|
84 |
24 |
48 |
191
1/2
|
340
3/16
|
|
|
8436-BG-36-AL
|
84 |
36 |
36 |
203
1/2
|
352
3/16
|
|
|
8436-BG-48-AL
|
84 |
36 |
48 |
203
1/2
|
352
3/16
|
|
|
8448-BG-36-AL
|
84 |
48 |
36 |
215
1/2
|
364
3/16
|
|
|
8448-BG-48-AL
|
84 |
48 |
48 |
215
1/2
|
364
3/16
|
|
|
|
|
ALUMINUM
CROSSOVER BRIDGE
|
|
|
|
|
|
|
|
|
Asymetrical
crossover
|
|
|
|
|
|
|
|
OSHA
STANDARD 1910.25 STAIRWAYS
|
|
|
|
|
|
|
Walking-Working
Surfaces and Personal Fall Protection Systems Final Rule
Frequently Asked Questions
|
The
intent of OSHAs Walking-Working Surfaces standard, 29
CFR Part 1910, Subpart D & I, is to increase the
protection of general industry employees and employers from
hazards associated with walking-working surfaces. The
rule making will significantly reduce the number of worker deaths
and injuries that occur each year resulting from
workplace slip, trip, and fall hazards. The final rule was published
on November 18, 2016, and became effective on
January 17, 2017. Some requirements in the final rule have compliance
dates after the effective date and will be
discussed in further detail below. This final rule and the associated
preamble, providing more detailed explanation of
the rule, is available on the Federal Register website at 81
FR 82494, Walking-Working Surfaces; Personal Protective
Equipment; Final Rule, November 18, 2016.
OSHA requirements are set by statute, standards, and regulations.
The Agencys interpretations explain these require-
ments and how they apply to particular circumstances, but they
do not create additional employer obligations. Note
that our enforcement guidance may be affected by legislative
or rule making changes to OSHA requirements. Also,
from time to time we update our guidance in response to new
information. To keep apprised of such developments,
you can consult OSHAs website at http://www.osha.gov.
This webpage provides guidance, in a question and answer format,
regarding OSHAs Final Rule, Walking-Working
Surfaces and Personal Protective Equipment, 29 CFR Part 1910,
Subpart D and I. These Frequently Asked Questions
(FAQs) are divided into five sections: general questions, rope
descent system (RDS) questions, outdoor advertising
questions, residential roof questions, and agricultural operation
questions. |
Standard
Stairs |
Does
the exception to the 9.5-inch riser height and 9.5-inch tread
depth requirements for stairs installed before
January 17, 2017 (§19210.25(c)(5)), also apply to stairs
designed and fabricated, but not yet installed, by that date? |
Stairs
with design drawings issued for construction or that were in
fabrication before January 17, 2017, but not
installed, will be in compliance if they met the previous requirements
for standard stairs. |
|
Under
the previous standard, stairs with a handrail that doubles as
a stair rail could have a rail height of 30 to 34
inches. If an employer's stairs were installed prior to January
17, 2017, must the rails have a minimum height of
36 inches if the stair rail doubles as a handrail? |
The
final rule does not affect stair rail systems and handrails
installed before January 17, 2017 that were in com-
pliance with the requirements in the old standard. |
|
Does
the requirement that standard stairs have a slope between 30
to 50 degrees apply to stairs installed after January
7, 2017. Therefore, the maximum angle for standard stairs is
45 degrees. |
Yes.
The final rule limits the maximum rise height and minimum tread
depth to 9.5 inches for standard stairs installed
after January 17, 2017. Therefore, the maximum angle for standard
stairs is 45 degrees. |
|
Are
stairs installed after January 17, 2017, that have an angle
of 50 degrees considered to be ships stairs? |
The
final rule defines ship stairs as a stairway that is equipped
with treads, stair rails, and open risers, and has a slope
of 50 to 70 degrees. Ship stairs must also comply with
§1910.25(b) and (e), such as a minimum tread depth of 4
inches, a minimum tread width of 18 inches, and a vertical clearance
above any stair tread to any overhead
obstruction of at least 6 feet 8 inches. |
|
What
if the doorway described in §1910.25(b)(5)(ii) and shown
in figure D-7 is perpendicular to the direction of
travel and opens onto the landing? Does the same dimension apply
to this condition? |
Yes.
As figure D-7 illustrates, Section 1910.25(b)(5) requires that
a platform be provided when a door or a gate opens
directly onto a stairway. For platforms installed after January
17, 2017, the final rule also requires that employers
ensure the swing of the door or gate does not reduce the "effective
usable depth" of the platform to less than 22 inches (§1910.25(b)(5)(ii)).
The preamble to the final rule describes effective usable
depth as the portion of the platform
beyond the swing of the door where a worker can stand when opening
the door (82 FR 82557). The provision applies
equally to stairway doors that are perpendicular to the direction
of travel. |
|
Are
fixed stairs attached to the exterior of tanks required to comply
with the requirements of §1910.25(b) or would
those stairs fall under the exemptions in §1910.25(a)?
The exception from the stair requirements in §1910.25(a)
only applies to stairs serving floating roof tanks, stairs on
scaffolds, stairs on self-propelled motorized equipment, or
stairs designed into machines or equipment. For stairs on
the exterior of other tanks, employers would have to ensure
they comply with the requirements in §1910.25(b) and (c). |
|
Would
winding stairs attached to tanks be required to meet the requirements
in §1910.25(d) for spiral stairs?
No. Section 1910.21(b) defines spiral stairs as a "series
of treads attached to a vertical pole in a winding fashion,
usually within a cylindrical space" (emphasis added). Winding
stairs attached to tanks do not have vertical poles;
therefore, they are not spiral stairs and must meet the requirements
of §1910.25(b) and (c). |
|
Based
on the height requirements for stair rails and handrails and
the requirements in Table D-2, are both stair rails
and handrails required on stairs that have two open sides and
are less than 44-in. wide?
Yes. Section 1910.28(b)(11)(ii) Table D-2 contains a printing
error, which OSHA will correct in a published notice.
For each flight of stairs with two open sides and a width of
less than 44 inches, column 4 of Table D-2 should state
"One stair rail system with hand rail on each open side"
is required. (See 81 FR 82611-12). |
|
|
|
|
|
|
Steel Crossover
Bridge, Stair Sections, Specific Height Requirements, Bar
Grating Stair Treads, Welded Handrails,
Structural Channel Stringers, Walkways Over Conveyors, Galvanized
Finish, BOCA Design 33°, and OSHA Design
45° from your source for material handling equipment.
|
Back to Product Page
|
HOME /
ORDER / SEARCH
/
QUOTE /
CONTACT US / ABOUT
US /
MY ACCOUNT/